Logo TFI

The small flame test determines the ignitability of a product. The surface and/or sample edge is exposed to a small flame (match size) in a vertical position. This test is essential for the classification according to EN 13501-1 and the CE marking.

Adjusting the flame height with a measuring gauge

Testing Properties

  • Ignitability of products subjected to direct impingement of flame according to EN ISO 11925-2
    (test for reaction to fire class Efl und E and prerequisite for Dfl-s1, Dfl-s2, Cfl-s1, Cfl-s2, Bfl-s1, Bfl-s2, A2fl sowie D-s1,d0; C-s1,d0; B-s1,d0; A2-s1,d0 ect.)
  • Resilient, textile, laminate and modular mechanical locked floor coverings (MMF)– Essential characteristics according to DIN EN 14041
  • Surfaces for sports areas – Indoor surfaces for multi-sports use – Specification according to DIN EN 14904
  • Parquet and wood flooring – Characteristics, evaluation of conformity and marking according to DIN EN 14904
  • Decorative wall coverings-rolls and panel form according DIN EN 15102

Suitable product types

  • coatings
  • floor coating systems
  • decorative wall coverings
  • resilient floor coverings
  • screeds
  • screed material and floor screeds wood flooring
  • modular mechanical locked floor coverings (MMF)
  • laminate floor coverings
  • parquet and wood flooring
  • clean-off systems
  • textile floor coverings
  • surfaces for sports floor areas
  • systems
  • underlays
  • wall and ceiling
Measurement of the flaming time and the total test duration